S200 99996202-US, S300 99996221-US, S300i 99996225-US, Active 20 99996023-US, Active 30 99996231-US, Active 30i 99996235-US, Prowler 920 99996201-US, Prowler 930 99996214-US, Discovery 99996201-DIS, Saturn 99996114-SAT, Cayman 99996135-SPL, Quantum 99996203-SPL, Premium 99996211-PIO. I will work through the steps you have listed here and hopefully it is a cable issue. To remove, turn off and unplug the power supply, then use the power cord to pull the robot to the surface of the water and to the pools edge. You can try replacing a couple of the boards in the box, but the endgame is almost always getting a new power supply within a month or two. You can easily switch between automatic cleaning cycles or manual with simple controls on the power supply. No matter the size, shape, or type of pool, nothing cleans like a Dolphin. For the first time operating it, youll need to unwind the power cord and stretch it out to remove the kinks. It is machine washable and can be hosed out, but takes some time. The impeller (in perfect condition-new) will not start, however, the wheels are working fine. Or cable (all 300 usd options). Jump toTest 2A - Check Power Supply. Most multimetershave morefunctions than we will use, For this series of tests, we will only be using the AC or DC voltage and continuity test functions. The meter should read close to 29V DC. Go toTest4. instructions for how to enable JavaScript in your web browser, Click Here to View Replacement Dolphin Pool Cleaner Parts, Motor Unit D.basic 3 Hour Ac New (99953003-assy). If you get 29V DC on the raw wire and you saw 0V DC when you tested the Amphenol Plug inTest 3B, you will need to run a continuity test on the plug itself. Call 303-985-0077 if you do not see the part you need or if you need assistance with pricing or troubleshooting. Exclusively at Wild West Pool Supplies, we can now proudly offer our best price yet on the Maytronics Power Supply9995670-US-ASSY. Drop enough of the power cord into the pool so that the cleaner can reach the farthest corner. Get your pool cleaner PSU, made by the original manufacturer, for a price that can't be beat! The DC out plug has continuity. If your Nautilus Plus no longer functions, don't fret! Posted: 4/18/2021, InyoPools Product Specialist Matt S. document.getElementById( "ak_js_1" ).setAttribute( "value", ( new Date() ).getTime() ); We love helping homeowners find quality cleaning products they can afford. I have checked all of the cables everything seems fine. Plug the power cord back into the wall and turn the Power SupplyON. Maytronics Dolphin Power Supply9995670-US-ASSYfeatures: The Nautilus Pro is one of the best pool cleaners on the market, and even the best PSUs have trouble lasting quite as long as this industry-leading pool cleaner. Thanks! Sometimes these jobs are done by one motor or two separate motors just mounted in the same box. For some people, it didnt climb the walls very well. You want to make sure you are testing the ends of the same wire for continuity. If the Pool Cleaner does not respond, your motor is bad. The "open" reading means there is no circuit continuity; I presume you need a new cable. If it reads 0V, move the probe to the other lead of the wall plug. This is a natural process; any PSU can only handle so many power cycles over the years before it starts losing efficiency, eventually hitting a point where it doesn't charge at the rate it used to. We discuss the danger and what you can do about it! I have three wires - a black, white and red. The voltageshould be around 29 volts, like the 2-wire version. The remote, according to several people, is pretty useless. Lakewood, CO 80232 DIAL METER FOR AC TEST - The AC side of the meter has two test ranges. Thanks. The cleaner doesn't remember a map of the pool. Do you want your pool cleaned every day, every other day, or every 3rd day? Is power pack 995670 compatible?? Cleanup.Expert is a participant in the Amazon Services LLC Associates Program, an affiliate advertising program designed to provide a means for sites to earn advertising fees by advertising and linking to amazon.com and affiliated sites. Since we will be testing for 120V from the wall socket, we will be setting the meter to 200. Posted: 7/26/2020, InyoPools Product Specialist Matt S. These are absolutely huge deals, across all of our pool and spa offerings. What is the model name or the serial number of your Dolphin cleaner? People reported various issues with customer service (CS). This is a natural process; any PSU can only handle so many power cycles over the years before it starts losing efficiency, eventually hitting a point where it doesn't charge at the rate it used to. You can drop it in, and it will go through its cleaning cycle. It is just a bell with no clanger. Posted: 8/20/2021, InyoPools Product Specialist Matt S. Me personally, I am very disappointed with this product. We will never hesitate to pass along any tips or advice. Posted: 4/14/2022, Tim Let it sink all the way to the floor. Your pool cleaner may be just a simple AC replacement away from being fully operational once more. TEST 4- CHECKPOWER SUPPLY FUSE - If you have an older style Power Supply, it will have a fuse inside that can be checked for continuity to see if it failed. Unfortunately, there isn't much left besides replace the motor or take it to a motor shop to see if it can be repaired.The replacement motor for the DX3 is the. I took apart the unit and found the drive gear and a guide wheel were busted up with bearings falling out. Reattach the Cable to the Power supply. Maytronics rigorously tests their products, and backs them with a warranty guarantee against short-term malfunctions. If you are testing for voltages above 200V and up to 600V, you would set your meter to 600V. Posted: 4/13/2021, InyoPools Product Specialist Matt S. It may take a little effort. Could you tell me why our power supply unit wont stay on. PRECAUTION 1 - During the operation of your cleaner, Make sure that your pool is free of toys or small objects that can get lodged in your cleaner and burn up the motor. When the cleaner does run intermittently, is it herky-jerkyor does it run as usual? Also, does one motor /impeller keeping working while the other turning off soon indicate a motor problem or maybe a yet to be found mechanical problem? Put the power supply about halfway down the long side of the pool and at least 12 feet from the edge. Place one probe in one of the holes in the female end of the power cord. There's no reason to even consider risking an unofficial replacement pool cleaner PSU. Chemical Startup of a Newly Filled Swimming Pool, Chemical Maintenance of a Newly Filled Spa, Virginia Graeme Baker Pool and Spa Safety Act Information, Maytronics Power Supplies - Dolphin Robotic Pool Cleaners. Posted: 5/29/2022, InyoPools Product Specialist Matt S. This is where this robotic pool cleaner really shines. Our customers who bought in years ago are now increasingly looking into replacing their aging power supplies. Whether or not the track spins could have more to do with guide wheels and brushes than the motor itself. the whole power supply is the. The power supply is putting out 21.2 VDc (measured right at power supply). After 2.5 minutes, the power light goes out, and the DC voltage drops to .01, then fades to 00. I have a more recent unit, so I seem to see a fuse solded to the board. Its machine washable but can be hosed out as well. Robotic pool cleaners like the Nautilus Plus draw a great deal of power for normal operation. It saves me time and energy, especially when the pool is opened and has a winters worth of stuff on the bottom of the pool. What is the part number of your power supply? It could be a bad transformer or board in the power supply. Using a Phillips head screwdriver, unscrew the middle screw and lift off the Impeller cover. Your pool cleaner may be just a simple AC replacement away from being fully operational once more. I check the power to the robot and it has 62 volts and will not come on and move. Filtration is what separates the good pool robots from the not-so-good ones. Maytronics 58984402LF Digital Power Supply Cable, How To Measure & Install A Swimming Pool Liner, This product is for the Maytronics cleaners only: S200 99996202-US, S300 99996221-US, S300i 99996225-US, Active 20 99996023-US, Active 30 99996231-US, Active 30i 99996235-US, Prowler 920 99996201-US, Prowler 930 99996214-US, Discovery 99996201-DIS, Saturn 99996114-SAT, Cayman 99996135-SPL, Quantum 99996203-SPL, Premium 99996211-PIO, Input: 100-125VAC 50/60 Hz 2A Output: DC 29V 120W, Black Power Cord is NOT included it is sold as a separate part number 5898412LF, Maytronics Cable For Digital Power Supply, 5898412LF, For the following Maytronics cleaners only: S200 99996202-US, S300 99996221-US, S300i 99996225-US, Active 20 99996023-US, Active 30 99996231-US, Active 30i 99996235-US. I tested the cable for continuity and its good. OVERVIEW OF TESTS - This picture lists the 6 tests we will conduct to isolate your Dolphin electrical problems. TEST 6A - CHECK THE DOLPHINCABLE - If you have 29V DC coming outof the PowerSupply into the Cable (See Step 3B) and 0V DCat the motor end of the Cable, you will want to run a continuitycheck on each wire in the Cable to verify that the Cable is broken and needs to be replaced.Remember to unplug the Cable at the PowerSupply end. Its packed with smart tech features and can clean an in-ground pool up to 50 feet within 3 hours. The Dolphin Supreme M4 uses the, I am not getting any voltage out of the unit. Posted: 8/16/2021, InyoPools Product Specialist Matt S. When used in conjunction with the 4 different cleaning modes, this little robot can pick up everything from leaves and sticks to sand and algae. This top-tier Maytronics Dolphin Power Supply9995670-US-ASSYis at 15% off only as long as our current stock holds out, though, so don't wait! Posted: 3/12/2022, InyoPools Product Specialist Matt S. Posted: 5/23/2020. Place the other probe onone of the leads on the other end of the cord thatplugs into the wall outlet. Once we sell out, we can't guarantee this amazing price. Posted: 4/5/2022, InyoPools Product Specialist Matt S. What do you think? TEST2C - If the reading on the meter is OV, Check for a break in the electricalwiring of the cord. If you suspect this to be the case, this replacement may be all you need to get your robotic pool cleaner back to 100% full functionality. Blue light on power source comes on. In our informative article, youll discover the causes of a cloudy pool and how to fix the problem. Posted: 9/3/2020, Rick Posted: 10/23/2020, LEP With all the different types of swimming pools available, such as in-ground and above-ground, it can be difficult to decide which one to get. Back to same problem. It comes on for a bit then the just turns off the reset button and test button wont work on the black power cable clicks off straight away. I forgot how to have my dolphin map the pool. Not only is pool maintenance business, in our spare time it's our hobby! Ifthe continuity checks are successful, check that you are getting a good connection at the end of the plug on the Power Cable and that all of the pins are in the Power Supply plug. My unit does not perform as advertised I can run this unit for 9hrs and still have to vacuum the pool manually. 13 year old Dolphin M4 Supreme suddenly stopped working my power light switch will light up but the 1 2 3 cycle lights will not come on. So, it sounds like the voltage is out of the desired range. Many robot pool cleaners are hit or miss at the waterline or dont even get that far up the wall. Posted: 12/9/2020, Don The power outlet, and supply cable test good, 120 v. When first powered on, the blue lights come on, and 29 v register on the DC out. The AC glass fuse on the board has power on both sides. If I unplug the cable and power on the power supply , the 3 lights blink and the power stays on like usual. 7777 W. Jewell Avenue spindl Once powered back on, the same cycling happens, lights stay on for 2.5 mins or so, power 29v on DC out, then fades to 00 again. Power supply lights up and I can select any of the three weekly programs, but the motor never starts either in the water or on dry land. If the meter shows 29V, you are getting power to the motor. The motor is receiving power but is not turning; if the shafts are frozen, the motor is dead and should be replaced. Figuring possibly a blown motor? No other automatic, residential pool cleaner comes close to Dolphin robots ease of use, performance, and reliability delivering years of cost-effective pool cleaning. It appears you found the issue, the wire is broken and the resistance reading is "open." the upper limits of which are labeled 2, 20, 200, and 600. Have you done any of the troubleshooting? Check out our guide on how to start a pool cleaning business. Posted: 8/17/2021, Laura 9995670, PD 5012, SN HG5012A10956 More about the Maytronics Power Supply9995670-US-ASSYRobotic pool cleaners like the Nautilus Plus draw a great deal of power for normal operation. [emailprotected]. The correct replacementfor your cable is the. REVIEW MULTIMETERBASICS - This is a picture of a typical multimeter. Posted: 9/8/2021, Johnathan Dixon I ran diagnostic tests on my Maytronics power supply, P.No. Posted: 8/11/2021, Pool Daddy Germs and bacteria cause swimming pool illnesses. Posted: 3/14/2022, Gerald T Tschura So it shouldnt be too hard to lift and drop into the pool. TEST3E - To retest thevoltage coming out of the Power Supply first TURN ON THE POWER. The only replacement parts I could find for the. Yes, if the motor is receiving power but still is not moving, you have a blown motor. PRECAUTION 2 - When your cleaner is not in use, pull it out of the pool and keep it unpluggedto avoid lightning and power surges. Okay Sounds like it is suppose to be 29 VDC. commercial I don't know if it is supposed to spin freely, turning both ways. TEST 1A - CHECKWALL OUTLET -The power at the outlet should be around 120V so set the meter for 200 on the AC side of the multimeter. Posted: 4/25/2022, Nautilus CC Plus Out of Water Test Trying to determine if i need a new motor unit, power supply. Posted: 5/26/2020, InyoPools Product Specialist Matt S. Or do you just want to clean it whenever you think about it? Can I replace that fuse or do I have to replace the whole board ? Or, it might starve an active unit from the necessary power for standard operation, leading to unexpected issues. Can you tell me what the voltage reading should be across the red wire? replacable? But that is a guess. PULL THE POWER CORD OUT OF THE WALL OUTLET. I would not recommend this product to anyone, yet to find any practical use for a scheduling option on the robots. Dolphin Pool Cleaner Power Supply 9995678-US-ASSY, The power supply was great quality and was delivered on time, 471 S Deseret Dr When I test my nautilus cc plus out of water, is is the track supposed to spin only one way, or spin one way, then reverse the other way? Dolphin pool cleaners offer the most efficient and cost-effective method for achieving a consistently clean pool. pool robotic cleaners ground automatic cleaner aquabot junior Maytronics Dolphin 9995670-US-ASSY Power SupplyPool Cleaner. DIAL METER FOR CONTINUITY TEST -A continuity test measures for a break in an electrical line, like the Dolphin Cleaner cable. Any boards or internal fuse etc. Trying to determine if my motor is faulty, or if spinning only one way out of water is normal. You show only 2 wires coming into the amphenol plug. TEST 2B- Insert the twomultimeterprobes into the female end of the power cord The meter should be set to 200V AC asused in Step 1. No humming or signs of life from the motors. Posted: 5/14/2021, Richard Have you tried testing the cable as mentioned in step 6A (Step 23)? Youll attach the power cord to the power supply and turn it clockwise to lock. Could this be a power supply issue or is something else likely? When powered on only the three blue lights,,, not the amber, The three blue lights flash for about a while then go out. Each of these tests may be broken down into a series of subtestssuch as Test 3a, Test 3b, etc, depending on the success or failureat each stage of the test. Amphenol plug (3 pins) DC voltage: 28, 26 and 1.9 for the different pin combinations Posted: 7/18/2020, Anonymous Maytronics Dolphin Pool Cleaner Power Supply | 9995670-US-ASSY, Maytronics Product Number:9995670-US-ASSY, Replacement AC adapter for Dolphin Nautilus Plus Robotic Pool Cleaners, Compatible with standard full AC power cords. So, why replace your entire unit if everything else is still in tip-top shape? It appears to be sealed pretty well. However, the caddy is very useful for transporting and storage. You have tested the pins on the power supply, but what about steps 17 to 23? The cartridges easily snap in and out and can be quickly hosed clean. If the fuse tests positive, the Power supply has an internal problem and you will have to replace the Power Supply. The Dauphine cleaner works great .But only stays in one area of the pool around a 20 foot area.Does not go to ends of pool.Vacuum works great just dont get around all or pool. Since then, hes worked in a variety of industries, including design and construction of luxury swimming pools. It only climbs a third of the way up the wall and has never cleaned the steps or the pool seats. Twist the plug counter-clockwiseuntil it comes out and thenslide it down the Cable. Insert the two meter probes into the socket of the AmphenolPlug. Homeowners with trees around the pool commented on how well this machine worked. Posted: 9/23/2020, CDS Does the 2.6v voltage difference between two powered pins mean the power supply is ok, or that it needs replacement? Posted: 12/8/2020, InyoPools Product Specialist Matt S. I think Laura and I are having the same issue except now my power supply will not turn on at all now. If continuity fails, you will have to replace theAmphenolPlug. Ran the tests recommended and no DC voltage comes out the amphenol plug or wires into back of plug. It's because of that exact demand that we explored finding ways to get a large order of this item in at the best price possible. Posted: 8/9/2021, InyoPools Product Specialist Matt S. Some customers mentioned how the components are easily taken apart if something breaks so you dont have to ship the whole thing for most repairs. An educated guess would lead me to say it is a bad motor. Just replace the cable or is the power supply bad as well? This guide shows you howto troubleshootthe electrical circuits of the MaytronicsDolphin Pool Cleaners so you can isolate your problem and replace the failed parts or parts. If you get 0V DC on the raw wire, you will have to test the fuse inside thePower Supply for continuity. Posted: 8/23/2021, Kevin Fitz Lowest Prices Guaranteed. One customer suspected the floats on the handle werent properly positioned, so thats something you might want to research. It has provided me and others a lot of good information. Thank You for your time. Either CS was unresponsive or requested they ship the whole unit back. The red wire is the ground. You are missing a '9' at the beginning of both of those part numbers. But leave it OFF for now. Then place the two probes from the multimeterinto the wall outlet. Theyre not super cheap. DIAL METER FORDCTEST -TheDC side of the meter hasfour test ranges. Virtually no explanation of the smart tech features. TEST 2A- CHECK POWER CORD - Pull the power plug out of the Power Supply to test the power cord between the wall outlet and the power supply. You would need to do some of the troubleshooting mentioned in the guide if you want any certainty. What is the part number for your specific power supply? For the following Maytronics cleaners only. You can also purchase disposable filter bags if you wish. For the most part, customers really appreciate how easy this machine is to set up and operate, despite the lackluster owners manual. Resistance of cable: 0.9, 0.6 and .OL (open) for the 3 different wires Lightweight and durable, this caddy makes storing and transporting your pool robot easy. The navigation system and scanning features allow this pool robot to clean the walls, floor, and waterline using the most efficient path for a quicker clean. It's for real. Depending on the age of the cleaner, it may be best to get a whole new unit because motors are expensive. Then place the meter probes into the plug on the motor end of the Cable. Posted: 4/21/2021, Vinny REASSEMBLY THE CLEANER - Plug the Cable back into the motor and secure it with the white Cable Retainer Plug. This is where the Dolphin Premier could use some improvement. Our pool maintenance expert, Luke Reed, earned his BS in Civil Engineering from Georgia Tech in 1998. For the premium price, thats disappointing. This deal isnot too good to be true. Privacy PolicyTerms & ConditionsImage Copyright, Above Ground Pump & Filter Equipment Set Parts. It sounds like your impeller motor has failed. Posted: 4/22/2022, InyoPools Product Specialist Matt S. dolphin triton robotic pool terrific trite cleaners Note: This model does not ship with a power cable. Its a 09/2005 model yellow. Posted: 3/18/2022, InyoPools Product Specialist Matt S. We rated the Dolphin Premier as #1 on our list for several reasons. caddy dolphin robotic triton maytronics cleaner assemble pool inyopools Is your swimming pool too murky to swim in? There's no exact date when this offer runs out, but you'll want to get yours soon. There is somethingwrong with the Cable. I have a 4 year old dolphin premier that now often does not start moving, o r stops moving after few seconds or minutes, while tge impeller keeos working. If you are testing the circuit for voltage, you need to go the length of the circuit to see where the voltage stops. The top impeller and drive tracks quit working. How can you rate it so high when it has had issues with cleaning pools with curved ends? TEST3A - CHECK AMPHENOLPLUG - Reconnect the power cord to the Power Supply. Then place a probe on either side of the plug as shown. Any thoughts? By submitting your payment, you agree to our terms and conditions. It will feel heavier than before due to the water and debris in the filters. If the continuity check on the fuse is negative, replace the fuse. TEST5D - Set the meter to 200 DC and check that the Dolphin Cable is attached to the Power Supply. Not quite sure how to interpret the voltage on the amphenol plug. TEST 5A - Remove theCleaner Cover by unscrewing the screws at each the 4 corners and liftingoff the Cover. If you do not have that, what is the model of Dolphin cleaner you own? PLEASE NOTE: Power Cable Sold Separately. Kaysville, UT 84037, Copyright 2022 All Rights Reserved. Copyright 2019-2020 Marina Pool Spa & Patio. What is the part number of the power supply? My Dolphin pool cleaner supply arrived right on time and works perfectly. Get your hands on the Maytronics Dolphin 9995670-US-ASSY Power Supply at our limited time offer of 15% off. Then drop us a line! Phone: 303-985-0077 Suite #2 Make sure to test both of the two circuits through the plug. The power supply comes on but the 3 leds for Does this indicate that a new power supply is needed? So why wait? I have checked/disassembled the moving parts outside the motor unit to make sure everything is clean and moving freely. The power supply is 2 years old. Be careful not to touch theprobes across the wires or you will short them out. Posted: 6/29/2020, InyoPools Product Specialist Matt S. Our guide including pros and cons can help you make that choice. A few customers noticed that the roller returned to its normal shape when they put the machine in the pool. Combine this with dual scrubbing brushes and the mapping software, and you get a more thorough clean faster than the more basic pool robots. At this point, if theCleaner is not still under warranty, it is usually cheaper to buy a new cleaner than sending the cleaner out for a motor replacement. TEST5B - Place the ends of a pair of needle-nose pliers into the holes on top of the Cable Retainer Plug. Authorized Service Center and Elite Dealer. Thinking about buying a pool? Its bad. Cleaner, crisper pool experiences are coming your way. Note how the wires areattached so you can replace them correctly when the plug is reattached. Though the reusable filter bag holds a lot of debris, its not particularly easy to clean out. Website creation in Evergreen, Colorado by AlphaPixel Reach. Multi-media filtration includes 3 filter options: bottom-load fine cartridge filters, ultra-fine cartridge filters, and a large fine filter bag. Hi. When running this test, the POWER MUST BE OFF, and the meter should be set at the continuity setting as shown. If you see 29V DC, the AmphenolotorPlug is good and you can gotoTest 5A to check the DolphinMotor. I took everything off the motor that would be a load and plugged it into the power supply, but get the same result. $10.50 Flat Rate Shipping available on all Maytronics Replacement Parts.

Sitemap 27