endobj /Length 2597 Operating Impressions, Questions and Answers: Vacron Intelligent Wide Dynamic High Definition Color Camera, DK-MBOX-030 DKnight Magicbox Wireless Speaker, BGW210, BGW210-700 ARRIS uDSL Wireless Residential Gateway, Panasonic KX-TGA402, 96NKX-TGA402 DECT 6.0 Handset, Download Climate 5000 Series Manual (32 pages). /OP false Use a vacuum pump and manifold ga, Bosch Climate 5000 Series 22 | Bosch Climate 5000 Series Multi Zone Ductless Air Conditioner / Heat Pump Installation Manual 05.2019 | Bosch Thermotechnology Corp. Data subject to change 9.3 Adding Refrigerant CAUTION: CONTAINS REFRIGERANT Refrigerant charging must be performed after wiring, vacuuming, and the leak testing. All electrical wiring must be done according to local and national regulations. 5. Note that there are two di erent types of drain joints depending on the type of outdoor unit. 31 0 obj Are you looking for an installer near you? 1. Charging with unsuitable substances may cause explosion, Installation Manual Bosch Climate 5000 Series Multi Zone Ductless Air Conditioner / Heat Pump | 23 Bosch Thermotechnology Corp. | 05.2019 Data subject to change 10 Electrical and Gas Leak Checks 10.1 Electrical Safety Checks After installation, con rm that all electrical wiring is installed in accordance with local and national codes / regulations, and according to the Installation Manual. 2. The Climate 5000 is designed for easy installation and has the flexibility to fit virtually anywhere. DO NOT exceed the maximum allowable quantity of refrigerant or overcharge the system. Therefore, keep the remote controller in a location where it can transmit the signal to the indoor unit properly. /HT /Default Press the MODE button to select COOL or FAN mode. Before bolting the outdoor unit in place, you must install the drain joint at the bottom of the unit. DO NOT bend the tubing more than 90 or more than 3 times. Set temperature, room temperature, or time depending on current mode and function. The Climate 5000 Ductless System delivers consistent temperature and humidity levels throughout the desired space by making automatic adjustments to meet your needs - at sound levels as low as 20 dBA. Displayed when remote controller is ON. Do you have any questions or suggestions for improvement? P65, 6 | Bosch Climate 5000 Series Multi Zone Ductless Air Conditioner / Heat Pump Installation Manual 05.2019 | Bosch Thermotechnology Corp. Data subject to change 2 Components The air conditioning / heat pump system installation requires the following components. >> /UCR2 /Default /op true Qf Ml@DEHb!(`HPb0dFJ|yygs{. User Manual 5 Bosch Remote Controller for Split Type Ductless Air Conditioner / Heat Pump | 9 How to use the buttons 5.2 Cooling /Heating/Fan operation Ensure the unit is plugged in and power is available. Norcool CU-350 Directions/installation/ Maintenance/delivery Conditions, Directions/installation/ maintenance/delivery conditions (24 pages), Panasonic CW-C140NU Installation And Operating Instructions Manual, Installation and operating instructions manual (24 pages), Sanyo SAP-K92A Technical & Service Manual, Euro-Line FC512CL Technical And Service Manual, Mitsubishi Electric MSZ-GF60VE2 Installation Manual, Mitsubishi Electric PAC-MK54BC Technical & Service Manual, Mitsubishi Electric MUZ-SF25VE-E1 Service Manual, Samsung AJ RBLDEG Series Installation Manual, Cooper & Hunter CHML-ID12NK Service Manual, Bosch Climate 5000 Installation manual (28 pages), Bosch Climate 5000 Installation, operation and maintenance manual (24 pages), Bosch Climate 5000 Service manual (64 pages), Bosch Climate 5000 Operation & users manual (16 pages). 1. Press the TIMER ON button to set the auto-on time of the unit. After connecting the copper pipes , Installation Manual Bosch Climate 5000 Series Multi Zone Ductless Air Conditioner / Heat Pump | 17 Bosch Thermotechnology Corp. | 05.2019 Data subject to change 8 Wiring WARNING: ELECTRICAL HAZARD Be sure to disconnect the power supply before working on the unit. Press the MODE button to select DRY mode. /OPM 1 1 0 | Bosch Remote Controller for Split Type Ductless Air Conditioner / Heat Pump User Manual 5.3 Dehumidifying operation 5.4 Timer operation Ensure the unit is plugged in and power is available. hwTTwz0z.0. AZ29E12DAPGE Zoneline Dry Air 25 Series Cooling and Electric Heat UnitSpecification Created 1/08390540For answers to your Monogram, GE Profile or GE appliance questions, visit our website at ge.com or call GE Answer Center service, 800.626.2000.Electrical WiringAll wiring, including installation of receptacle, must be made in accordance with local electrical codes and regulations.No Zoneline AZ29E12DAP Air Conditioner Dimensions and installation information, 2. 27 0 obj 1. 2. /op false stream /OPM 1 1. F565860ENGLISH ENGLISH 2 ~ 92 ~ 9Before operating the unit, read these Before operating the unit, read these operating instructions thoroughly and operating instructions thoroughly and keep them for future reference.keep them for future reference.SVENSKA SVENSKA 10 ~ 1710 ~ 17Innan du anvnder enheten, ls noga igenom Innan du anvnder enheten, ls noga igenom denna bruksanvisning och spara CU-CE7HKE Air Conditioner Operating instructions manual, 44. >> For installing or removing the remote controller, move it up or down in the holder. endobj ON/ OFF SIL ENCE FP TIMER ON MO DE TEMP TIMER OFF FAN SLEEP TURBO SE LF CLEAN SW IN G DI RE CT LED F OLLOW ME Bosch Remote Controller For use with Bosch Split-Type Ductless Air Conditioner / Heat Pump User Manual. User Manual Bosch Thermotechnology Corp. | 12. /N 3 We are sure you will nd your new portable air conditioner a pleasure to use and a great asset to your comfort. The electrical, refrigerant, and condensate drain lines that connect the indoor and outdoor units run through a 3 diameter hole in an exterior wall, making it both unobtrusive and easy to install. Ensure that there is enou, Installation Manual Bosch Climate 5000 Series Multi Zone Ductless Air Conditioner / Heat Pump | 11 Bosch Thermotechnology Corp. | 05.2019 Data subject to change Split type outdoor unit mounting dimensions Outdoor Model Outdoor Unit Dimensions mm (in.) Before you use the portable air conditioner, we recommend that you read through the whole user manual, which provides the description of the portable air conditioner and its functions.To avoid the U31175 LU4 9QQ Air Conditioner Operation & users manual, 27. /BG2 /Default The following keywords are de ned and can be used in this docu, Installation Manual Bosch Climate 5000 Series Multi Zone Ductless Air Conditioner / Heat Pump | 5 Bosch Thermotechnology Corp. | 05.2019 Data subject to change WARNING: This product can expose you to chemicals including Lead and Lead components, which are known to the State of California to cause cancer and birth defects or other reproductive harm. | Bosch Remote Controller for Split Type Ductless Air Conditioner / Heat Pump User Manual 3 Operation of buttons 7 1 ON/ OFF 2 MO DE 3 FAN TEMP 4 TURBO 8 TIMER ON 9 TIMER OFF SLEEP 5 6 SILE NCE FP SELF CLEAN SWING DIRECT LED FOLLOW ME 10 11 12 13 14 Figure 2 1. | Bosch Remote Controller for Split Type Ductless Air Conditioner / Heat Pump Data subject to change User Manual 12.2016 | Bosch Thermotechnology Corp. << Three-Zone system /SA true Remove tape from ends of pipe when ready to perform aring work. Name Quanity Drain join, Installation Manual Bosch Climate 5000 Series Multi Zone Ductless Air Conditioner / Heat Pump | 7 Bosch Thermotechnology Corp. | 05.2019 Data subject to change 3 Installation Summary Figure 1 LN 1 2 3 MC MC 4 5 Install the outdoor unit (Page 10) Evacuate the refrigeration system (Page 21) Connect the wires (Page 17) Connect the refrigerant pipes (Page 14) Perform a test, Bosch Climate 5000 Series 8 | Bosch Climate 5000 Series Multi Zone Ductless Air Conditioner / Heat Pump Installation Manual 05.2019 | Bosch Thermotechnology Corp. Data subject to change 4 Installation Diagram Figure 2 More than 5.9in More than 78.7in 1 5 3 2 4 6 Two-Zone Three-Zone Four-Zone Five-Zone More than 4.7in More than 4 .7in Air Filter Air Filter More than 4.7in Air Filter More than 4.7in More than 23.6in More than 11.8in More than 11 .8in More than 23.6in Loop a connective , Installation Manual Bosch Climate 5000 Series Multi Zone Ductless Air Conditioner / Heat Pump | 9 Bosch Thermotechnology Corp. | 05.2019 Data subject to change 5 Speci cations Number of units that can be used together Connected units 2-5 units Compressor stop/start frequency Stop time 3 min or more Power source voltage Voltage uctuation within 10% of rated voltage Voltage drop during start within 15% of rated voltage Interval unbalance within 3% of rated voltage Table 3 2 Zone System 3 Zone System 4 , 10 | Bosch Climate 5000 Series Multi Zone Ductless Air Conditioner / Heat Pump Installation Manual 05.2019 | Bosch Thermotechnology Corp. Data subject to change 6 Outdoor unit installation Step 1: Select installation location The outdoor unit should be installed in the location that meets the following requirements: Place the outdoor unit as close to the indoor unit as possible. tqX)I)B>== 9. User Manual Bosch Remote Controller for Split Type Ductless Air Conditioner / Heat Pump | 5 2 Remote controller specifications Model / Part Number RG57A6 / 7738005548 Rated Voltage 3.0V (Alkaline AAA 2) Transmission Distance up to 25 ft Environment 23F ~140F Table 1 ON/ OFF SIL ENCE FP MO DE TIMER ON TEMP TIMER OFF FAN SLEEP TURBO SE LF CLEAN SWING LED DIRECT F OLLOW ME Figure 1 Bosch Thermotechnology Corp. | 12. Doing so can damage the unit or impact its functionality. Use all of the installation parts and components to install the air conditioner. Press the "check switch" on the outdoor unit PCB board for 5 seconds until the LED disp, 26 | Bosch Climate 5000 Series Multi Zone Ductless Air Conditioner / Heat Pump Installation Manual 05.2019 | Bosch Thermotechnology Corp. Data subject to change 13 Features and Operation 13.1 Protection of the Air Conditioner Compressor protection The compressor cannot restart for 3 minutes after it stops. /BG2 /Default /SA true /UCR2 /Default To set the Auto-on time. >> Warnings Warnings in this document are identied by a warning triangle printed against a grey background. Please contact us via this form! /Type /ExtGState /Alternate /DeviceRGB $O./ 'z8WG x 0YA@$/7z HeOOT _lN:K"N3"$F/JPrb[}Qd[Sl1x{#bG\NoX3I[ql2 $8xtr p/8pCfq.Knjm{r28?. Improper connections may cause electrical malfunction, injury and , 18 | Bosch Climate 5000 Series Multi Zone Ductless Air Conditioner / Heat Pump Installation Manual 05.2019 | Bosch Thermotechnology Corp. Data subject to change 8.2 Wiring Diagrams WARNING: ELECTRICAL HAZARD Connect the connective cables to the terminals, as identified, with their matching numbers on the terminal block of the indoor and outdoor units. United States and Canada Bosch Thermotechnology Corp. 50 Wentworth Avenue Londonderry, NH 03053 Tel: 866-642-3198 Fax: 954-776-5529 www.boschheatingandcooling.com BTC 770001103 B / 12. When the air conditioner is installed in a small room, measures must be taken to preven, Installation Manual Bosch Climate 5000 Series Multi Zone Ductless Air Conditioner / Heat Pump | 15 Bosch Thermotechnology Corp. | 05.2019 Data subject to change 4. 2. , Installation Manual Bosch Climate 5000 Series Multi Zone Ductless Air Conditioner / Heat Pump | 3 Bosch Thermotechnology Corp. | 05.2019 Data subject to change Table of Contents 1 Key to Symbols and Safety Instructions 4 1.1 Key to Symbols 4 1.2 Safety 4 2 Components 6 3 Installation Summary 7 4 Installation Diagram 8 5 Speci cations 9 6 Outdoor unit installation 10 7 Refrige, Bosch Climate 5000 Series 4 | Bosch Climate 5000 Series Multi Zone Ductless Air Conditioner / Heat Pump Installation Manual 05.2019 | Bosch Thermotechnology Corp. Data subject to change 1 Key to Symbols and Safety Instructions 1.1 Key to Symbols Warnings Warnings in this document are identi ed by a warning triangle printed against a grey background. Distance A Distance B BMS500-AAM018-1CSXRA 845x702x363 (33.27x27.6x14.3) 540 (21.26) 350 (13.8) BMS500-AAM027-1CSXRA, BMS500-AAM027-1CSXHB, BMS500-AAM036-1CSXRA, BMS500-AAM036-1CSXHB 946x810x41, 12 | Bosch Climate 5000 Series Multi Zone Ductless Air Conditioner / Heat Pump Installation Manual 05.2019 | Bosch Thermotechnology Corp. Data subject to change Drain joint installation Heat pump units require a drain joint. /BG2 /Default 1 2 | Bosch Remote Controller for Split Type Ductless Air Conditioner / Heat Pump COMBINED TIMER (Setting both ON and OFF timers simultaneously) TIMER OFF TIMER ON (On Stop Start operation) This feature is useful when you want to stop the air conditioner after you go to bed, and start it again in the morning when you wake up or when you return home. User Manuals, Guides and Specifications for your Bosch Climate 5000 Air Conditioner, Air Handlers. No obstacles near the inlet and outlet of the unit that might cause poor performance or pr, Installation Manual Bosch Climate 5000 Series Multi Zone Ductless Air Conditioner / Heat Pump | 25 Bosch Thermotechnology Corp. | 05.2019 Data subject to change 12 Automatic Wiring/Piping Correction Function Climate 5000 models now feature automatic correction of wiring/piping errors. , United States and Canada Bosch Thermotechnology Corp. 65 Grove Street Watertown, MA 02472 Tel: 866-642-3198 Fax: 603-965-7581 www.boschheatingandcooling.com BTC 769003106 A / 05.2019 Congratulations Congratulations and thank you for choosing our portable air conditioner. Panasonic Corporation 2015 Order No: PAPAMY1505100CE Air Conditioner Outdoor Unit CU-3E19RBUCU-4E24RBUDestinationU.S.A.CanadaPlease file and use this manual together with the service manual for Model No. 1. /SA false 25 0 obj )L^6 g,qm"[Z[Z~Q7%" 26 0 obj >> Press the TIMER OFF button. Bosch Thermotechnology Corp. 2022, all rights reserved, Climate 5000 - Engineering Submittal Sheets, Water-to-Air Geothermal Heat Pump Systems, Water-to-Water Geothermal Heat Pump Systems, Product Approvals, Certifications, Recalls & Regulatory Info, Efficient (up to 25 SEER rating) and super quiet (as low as 20 dBA), Simplified installation and maintenance, no ductwork required, Multi-part air filter system cleans air, reduces potential allergens and odors, Single and Multi Zone configurations for maximum indoor comfort.

Sitemap 7