ET Monday through Friday or online at www.gamewell-fci.com and click on "Safety Bulletin" or contact Notifier at 800-289-3473 from 7 a.m. to 7 p.m. Intelligent devices with integrated communication for performances that easily surpasses conventional devices. The Nest Protect, for example, uses a photoelectric split-spectrum sensor that is considered superior to the ionization sensor used in many older devices and which is more prone to false alarms. Ceiling or wall mounting. Middle East Air velocity rating from 100 ft/min to 4,000 ft/min. *** Replaces FAPT-851 ***. The lowest-priced brand-new, unused, unopened, undamaged item in its original packaging (where packaging is applicable).Packaging should be the same as what is found in a retail store, unless the item is handmade or was packaged by the manufacturer in non-retail packaging, such as an unprinted box or plastic bag.See details for additional description. Perhaps the biggest benefit of a smart smoke detector: No more hunting down midnight chirps, since youll also get phone-based notifications about dying batteries. Optional relay, isolator and sounder bases. Smart home hub support: If you want to integrate your smoke alarm with the rest of your home, consider whether it is supported by a major smart home hub. Here are our picks for the best options on the market today. Mounting base included. The molded plastic drain pan located at the bottom of the evaporator coil can overheat, melt and deform, posing a fire hazard. Non-Addressable Initiation. Norway It is a normally-open device designed especially for fire detection and alarm systems. PLUS. Ceiling or wall mounting. Color-coded lights on the alarm itself are another plus. It is compatible with the NFS-3030, NFS2-3030, NFS-640, NFS2-640, and NFS-320 in FlashScan or CLIP mode, as well as multi-criteria fire/CO detector is a plug-in, addressable device that With only one device to install and align, this single-ended optical beam solution saves time and money on large area applications. detection. B200S series intelligent sounder bases (B200SCOA series in Canada) are recommended for use with FCO-951 Series IntelliQuad Unique ability to detect all four major elements of a fire, Automatic drift compensation for smoke and CO sensors. Click Ok if you wish to continue to the website; otherwise, click Cancel to return to our site. The SMART4 combines 4 separate sensing elements to act as a single unit. The X-Sense XS01-WT isnt nearly as smart as the much more sophisticated Nest Protectit wont warn you of dangerous levels of carbon monoxide in your home, and you cant interconnect multiple units so that when one sounds off, theyll all sound offbut its $40 list price makes it a compelling home-safety value. LED alarm. You may wish to review the privacy policy of the external site as its information collection practices may differ from ours. best detection strategy offering heightened immunity to nuisance Portable gas detectors. Google Maps Location. The photoelectric smoke sensor can malfunction and cause the fire alarm system to fail to alert occupants in commercial buildings of a fire. As such, they are essential life-safety devices. Miami, FL 33126 LED alarm. Something went wrong. Because the potential exists for dangerous levels of CO to accumulate in almost any building, legislation mandating the use of CO detection in commercial spaces continues to increase across the U.S. and Canada. UL, CSFM Listed and FM Approved. Ideal applications are warehouses, atriums, aircraft hangers, sporting arenas and concert halls. UL, CSFM Listed and FM Approved. FM, CSFM, BSMI and CCCF Approved. Call CPSCs Hotline at 800-638-2772 (TTY 301-595-7054). approach enables enhanced sensitivity to real fire with heightened Tyco Simplex 4098-9733 TrueAlarm Analog Heat Sensor with three user-selectable sensitivities. Simplex 4098-9612 Electronic Heat Detector for Two-Wire Direct Connect with fixed temperature operation. It uses an innovative thermistor sensing circuit to produce 135F fixed high-temperature detection for cost-effective, intelligent property protection. Photoelectric sensors detect airborne particles associated with smoke. It features a smoke-sensing chamber and patented optic block designed to amplify signals from smoke, but diminish stray internal reflections that can cause false alarms. The B200S/B200SCOA For the most part, smart smoke alarms tend to work almost identically. With FlashScan and CLIP protocol systems. Status LED indicators. The IntelliQuad PLUS FCO-951/-IV and FCO-951A/-IV advanced Most of the smart smoke alarms we evaluated are available in either format and cost the same. Unique ability to detect all four major elements of a fire. This intelligent, addressable detector includes point ID capability that enables each detector address to be set with rotary address switches to provide exact detector locations. detector fsp notifier We distribute Once installed and powered up, you download the relevant app and connect to the device wirelessly. The glass Coda pendant light fixtures can detach from their electrical cord, causing the fixture to fall unexpectedly, posing a risk of injury from impact. 24 VDC. Italy mandating the use of CO detection in commercial spaces continues IP44. He contributes regularly to TechHive, PCWorld, and Wired, and operates the websites Drinkhacker and Film Racket. Partners: 4330 East-West Highway Bethesda, MD 20814, Contact Us: 800-638-2772 (TTY 800-638-8270) 2075 standard for system-connected life safety carbon monoxide Alarm Signal Devices. particulate and enhanced sensitivity to real fire. Google Maps Location, 1981 Wells Road Gamewell-FCI at 800-633-1311 from 7 a.m. to 7 p.m. The FPTI-951 Multi Criteria Photo/Temp/Infrared (PTIR) Detector from Honeywell NOTIFIER is an intelligent, multi-criteria detector incorporating photoelectric, thermal and infrared detection principles to sense a wider range of fires with greater accuracy. The model number, date codes and Honeywell or Notifier are printed on the back label of the smoke sensor. Benelux For CO, the detectors electrochemical sensing cell creates a separate signal for life safety CO detection. Fast Track recalls are initiated by firms, who commit to work with CPSC to quickly announce the recall and remedy to protect consumers. Moreover, they minimise the nuisance, expense and productivity loss associated with false alarms. Tyco Simplex 4098-9714 TrueAlarm Analog SSD Photoelectric Smoke Sensor with three user-selectable sensitivities. The FSP-951T photoelectric detectors unique optical sensing chamber is engineered to sense smoke produced by a wide range of combustion sources. and UL 521 listing requirements for fire detection as well as the UL As such, they can not only save your life, they can also protect what is likely to be your single biggest financial investment. Many smart smoke detectors hook into additional smart home gear and IFTTT, so an alarm can trigger your smart lighting to flash or change color when danger is detected. The B200S-LF-WH Sounder Base adopts the same address as the detector, but uses a unique device type on the loop. notifier fsi fst 851r This approach enables enhanced sensitivity to real fire with heightened immunity to nuisance particulate. GasDetectorsUSA.com provides a wide variety of industrial gas leak detection devices including toxic, oxygen and CPSC.gov is an official website of the United States government. Two-wire SLC connection and 360 viewing angle. And, of course, speedy push notifications to your phone are a must in the smart alarm space. The smoke sensors are round, ivory in color, and measure four inches in diameter. The 302-EPM-135 Thermotech rate-anticipation heat detector from Honeywell NOTIFIER operates within a controlled range of two to three degrees of their set points, regardless of the speed or rate of temperature rise. Notifier ISO-X Fault Isolator Module for Notifier Onyx and CLIP series Fire Alarm Control Panels (FACPs). The FSV-951R is a high-sensitivity photoelectric smoke detector designed for Very Early Warning Fire Detection and to protect valuable assets and operations where systems must remain functioning at all times. UL 268 7th edition, UL 521, and UL 2075 listed; CAN/ULC S529, Separate audible signal for fire or CO alarm when used with a B200S series base (B200SCOA series in Canada). might cause single sensing detectors to false alarm. Orange Park, FL 32073 The sensitivity can be programmed using the control panel software to suit the environment. The Fire Alarm Control Panel (FACP) can use that address to command an individual sounder or a group of sounders to activate. The FCO-851(A) should be used in conjunction with the B200S(COA) intelligent sounder base, which can generate either a Temp 3 pattern for fire or a Temp 4 pattern for CO alarm indication. GasDetectorsUSA.com provides a wide variety of industrial gas leak detection devices including toxic, oxygen and Linking to this external site does not constitute an endorsement of the site or the information it contains by CPSC or any of its employees. Consumers should immediately contact Gamewell-FCI or Notifier to receive a free replacement photoelectric smoke sensor. Multiple sensors and communication can greatly reduce nuisance Consult the factory for the lat- Some detectors will do both, so you dont need to deployand monitor the batteries inmore than one device. ET Monday through Friday or online at hwll.co/CPSCsafetyFSP-951-IV. That said, simulating smoky conditions can reveal a little about how sensitive a detector is. China The IntelliQuad PLUS Series detector meets both UL 268 7th edition X-Sense Mini Wireless Interconnected Smoke Detector (3-pack model XS01-WR) review, Best smart home systems for a connected domicile, Best smart lighting for your connected home. Hong Kong The IntelliQuad PLUS FCO-851 Advanced Multi-Criteria Fire/CO Detector is a plug-in, addressable device that provides both fire and carbon monoxide (CO) detection. detect with the human senses. The B200S Sounder Base adopts the same address as the detector, but uses a unique device type on the loop. As well, you can consider the general consensus about the underlying technology in a smoke detector. When shopping, pay close attention so you dont end up with the wrong type. If youre upgrading a hardwired model, its important that you replace all the detectors in the chain with the same make and model. The FCO-851 listed to the UL 268 standard for smoke detectors as well as the UL 2075 standard for system-connected life safety carbon monoxide monitoring. Notifier FSV-951R Series Very Intelligent Plug-in Early Warning (VIEW) Laser Smoke Detector. Certified for seismic and marine applications. Copyright 2022 IDG Communications, Inc. (FACP) output capable of generating the System Sensor synchroni- In and products. Smart smoke and carbon monoxide detectors dont just sound the alarm, they also alert your smart phone and more. South Africa Canadian models meet listing requirements of CAN/ULC Ideal for both system operation and building design, this device is a low-profile, intelligent, rate-of-rise thermal sensor that provides cost-effective, intelligent property protection. The FCO-951 Series Advanced Multi-Criteria Fire/CO Detector from Honeywell NOTIFIER incorporates photoelectric, thermal, infra-red and carbon monoxide detection principles, providing both fire and CO detection. The B224BI-WH Isolator Detector Base is an intelligent device with a 6.2 diameter and 14 to 24 AWG wire gauge. UL and ULC Approved. The blocked vent temperature switch (BVTS) can malfunction, which can cause the release of gases, including carbon monoxide (CO), into consumers homes, posing a risk of carbon monoxide poisoning. The Honeywell NOTIFIER range of high-performance addressable detectors provides fast and reliable response to fires. Smart smoke and CO detectors are among the most useful categories of smart home gear because they offer critical advantages over dumb versions of the same product. Deaths, injuries, and property damage from consumer product-related incidents cost the nation more than $1 trillion annually. For inquiries relating to potential partnerships or joint venture ideas, send an email to sales@GasDetectorsUSA.com or call us at 281-643-0080. Dual electronic thermistors add 135F (57C) fixed temperature thermal sensing on the device. FM (Class 1 Div 1 & 2) and IECEx approved (Made by Det-tronics). Per UL standard 2075, the FCO-951 Series has been tested to the agencies, or listing may be in process. Multi-Point gas controllers. Recalled -IV Intelligent Photoelectric Smoke Sensor, Example product label indicating data code location, Example carton label indicating data code location, Daikin Comfort Technologies Manufacturing (formerly Goodman Manufacturing Company, L.P.) Expands Recall of Evaporator Coil Drain Pans to Include Those Installed with Non-Condensing Gas Furnaces Due to Fire Hazard, Laars Heating Systems Company Recalls Residential Boilers Due to Carbon Monoxide Hazard, Loctek Recalls Fleximouts Overhead Garage Storage Racks Due to Impact Injury Hazard, Tech Lighting Recalls Coda Pendant Light Fixtures Due to Impact Injury Hazard (Recall Alert), SunVilla Corporation Recalls Solar LED Market Umbrellas Due to Fire and Burn Hazards; Sold Exclusively at Costco (Recall Alert), TJX Recalls Egg Chairs Due to Fall Hazard; Sold at Marshalls, T.J. Maxx, HomeGoods and Homesense Stores, Office of Equal Employment Opportunity and Minority Enterprise, Honeywell Recalls Gamewell-FCI and Notifier Photoelectric Smoke Sensors Sold with Fire Alarm Systems Due to Failure to Alert of a Fire. detection. CPSC does not control this external site or its privacy policy and cannot attest to the accuracy of the information it contains. smoke, supports the use of the IntelliQuad PLUS Series detector in Federal law prohibits any person from selling products subject to a Commission ordered recall or a voluntary recall undertaken in consultation with the CPSC. some cases, certain modules may not be listed by certain approval It functions in a temperature range of 0C to 49C. zation pulses. to grow. But theres no guarantee that feature will work if you have a mix of devices from different manufacturers wired together. *** Replaces FSP-851 ***. Semi-addressable Fire Alarm Control Panel, Fixed temperature model factory preset to 135F (57C), Rate-of-rise model, 15F (8.3C) per minute, High temperature model factory preset to 190F (88C), Universal application: can be used in all areas for any type of occupancy, Hermetically sealed: Shock resistant, corrosion resistant, and tamper-proof, Explosion-proof for installation in hazardous locations, Unique ability to detect all four major elements of a fire, Air velocity rating from 100 ft/min to 4,000 ft/min, Adjusts to square and rectangular mounting configurations, Patented tool-free, plug-in sampling tubes, Fast, easy, and intuitive beam alignment indicated by directional LED arrows, Long range coverage of 16-328 ft (5-100 m) is standard; no separate long-range kit required, Highly resistant to building movement; tolerates +/- 1 movement, Resistant to strong light sources; does not alarm when saturated by sunlight, Automatic sensitivity threshold level settings and drift compensation, 50 horizontal and 20 vertical beam adjustment, Remote test station capable for electronic simulated smoke test from ground level, Optional heater kit available for the reflector, Very Early Warning Fire Detection capability. Thermistor based. NOTIFIER by Honeywell ONYX Series NFS-320 Intelligent Addressable Fire Alarm Control Panel. Optional relay, isolator and sounder bases. ET. New Notifier Opal Detectors Improve Flexibility and Reduce Lifetime Costs, Notifier by Honeywells Smart3 and Smart4 Provides Intelligent Fire Detection for The University of Northampton, Detector Selection and False Alarm Prevention. UL, FM, CSFM, MEA and BSA Approved. At $119, the Nest Protect isnt cheap, but pricier options are out there. The smoke sensors have the following brand names, model numbers, date codes, and configuration. Sophisticated algorithms maximize the advantages of the sensor types creating our In testing, our phone was alerted almost immediately, and the app couldnt be simpler to master. It uses an innovative thermistor sensing circuit to produce 190F fixed high-temperature detection for cost-effective, intelligent property protection. alarms compared to single sensing methods. Get Notified About Each Recall via Email. ademco Alarms are varied, integrated lighting is color-coded based on the type of threat, and the product includes helpful voice alerts when activated. The FST-951R intelligent addressable detector from Honeywell NOTIFIER features point ID capability that enables each detector address to be set with rotary address switches to provide exact detector locations. R8S4B10, item 1 NOTIFIER FSCO-951 CARBON MONOXIDE DETECTOR FIRE ALARM, item 2 Notifier FSCO-951 Carbon Monoxide Detector, item 3 NOTIFIER FSCO-951 CARBON MONOXIDE DETECTOR, FREE SHIPP SAME DAY 504, 5.0 out of 5 stars based on 1 product rating, 4.3 out of 5 stars based on 4 product ratings. Thermistor based. TechHive helps you find your tech sweet spot. It is a normally-open device designed especially for fire detection and alarm systems. Sign up for our e-newsletter. Sweden Smoke and CO: Your home needs to warn against the danger of carbon monoxide as well as smoke. CO is a colorless, odorless, and deadly gas that is virtually impossible to detect with the human senses. NEMA 1. Interconnectivity: Some devices support an interconnectivity feature, so if one alarm goes off, all the other alarms in the house will go off as well. fsp notifier detector flanged detectors Tyco Simplex 4098-9754 TrueAlarm Multi-Point Analog Photoelectric and Thermistor Sensor for Early Fire Detection (smoke and thermal activity). info@rybbfirealarm.com IDNet communication. Flame Detectors. Gas Leak and Flame Detectors, Analyzers, Alarm Devices and Calibration Gas, Gas Detectors (parking Garages And Tunnels), Notifier IntelliQuad PLUS FCO-951 Advanced Multi-Criteria Fire/CO Detector with four unique sensing elements: Carbon Monoxide (CO) electrochemical sensor, Infrared (IR) sensing measure, Photo-electric smoke detection and Thermal detection. The device installs on the ceiling or high on the wall (typically replacing an old-school smoke alarm in the same location), either using batteries or in-wall power. ademco honeywell Engineered to deliver reliable fire detection and protection, each of these devices boast a sleek, low-profile design that fits perfectly into any kind of ambience. Advanced laser light source and 360 viewing angle. It is a normally-open device designed especially for fire detection and alarm systems. The Honeywell NOTIFIER FPC-951 is an intelligent, multi-criteria detector incorporating photoelectric and carbon monoxide (CO) detection principles. Biogas and Combustion Analyzers. Supports up to 159 detectors and 159 modules. France Notification variety: A loud siren is expected, but voice alerts are quite handy: They not only tell you what type of hazard has been detected, but also alert you to its location and can even tell you how to respond (whether thats opening a window or calling 911). A smart smoke alarm or CO detector will alert you to danger from smoke, fire, or a malfunctioning appliance even when youre not home. IDNet or MAPNET communications. SMART4 dynamically adjusts the detection profile of the device in response to the input from the sensors. +1 (855) 500-6857 It normally operates at a high immunity level, changing to become very sensitive to fires when fire characteristics are sensed. We didnt test interconnectivity features in our review since we tested single alarms individually, so check specifications when shopping if this feature sounds useful. The FSB-200 reflected beam smoke detector from Honeywell NOTIFIER is designed for spacious rooms, open areas and high ceilings. Germany The 302-ET-135 Thermotech rate-anticipation heat detector from Honeywell NOTIFIER operates within a controlled range of two to three degrees of their set points, regardless of the speed or rate of temperature rise. Mexico Includes 0-20 mA output, LED and Alarm, Auxiliary and Fault relays. Infrared sensors discern light patterns in the environment as an additional data point for alarm determination. UL and ULC Approved. The listings and approvals below apply to the FCO-951 Series. Copyright 2022 RYBB - Designed & Powered By, Notifier FSP-851R Intelligent Smoke Detector, Brk Electronics DHI851DC Duct Smoke Detector, Simplex 4098-9794 Sounder Base P/N:0677337CN, Download the Specification sheet in *.pdf format. IDNet or MAPNET communications. It offers an addressable solution that meets the UL 2075 standard for system-connected life safety carbon monoxide detection. UL, ULC, CSFM and FM approved. The FS-OSI-RI detector is a combined transmitter/receiver and is compatible with NFW-50X, NFW- 100X, NFS-320, NFS2-640, and NFS2-3030 fire alarm control panels in FlashScan or CLIP mode. detector notifier fsb 200s alarm intelligent beam smoke sensor fire Non-Addressable Initiation. One of the U-shaped buckles on the supporting cables can fail, posing an impact injury hazard to the user or bystander if the rack falls. The 302-AW-135 Thermotech rate-anticipation heat detector from Honeywell NOTIFIER operates within a controlled range of two to three degrees of their set points, regardless of the speed or rate of temperature rise. In this case, though, the outlay is worth it. Non-Relay. Look for a system that supports multiple users through an invitation system. Carbon Monoxide sensors detect this by-product of fire for accurate fire detection. USA, Copyright Honeywell International Inc 2003-2022 | Notifier by Honeywell | Registered office: Honeywell House, Skimped Hill Lane, Bracknell, Berks, RG12 1EB, UK, Voice Alarm, Public Address and Loudspeakers, Emergency Lighting Central Battery Systems, NOTIFIER_Addressable_Multi-Criteria_SMART4_Detector_Specification.docx, NOTIFIER_Addressable_Multi-Criteria_SMART4_Detector_Specification.pdf. High noise immunity. Installed just like a smoke detector and works perfectly. It is UL/ULC listed. {iyzt)_jna_[aYc1Jyu5m4q35}S,&vn:laysC,.7>.6/g6/-{fTayp:70/,;oBg. UL, FM, and CSFM Approved. Notifier DNR intelligent Photoelectric Duct Smoke Detector for mounting to round or rectangular ducts. Thermal sensors detect heat and rate-of-rise (135F fixed temperature threshold). Australia *** replaces FSC-851 ***, 2.7" (69 mm) installed in B200S series sounder base, 6.875" (175 mm) installed in B200S series sounder base, 15% to 90% Relative Humidity, Non-condensing, 200 uA (one communication every 5 seconds with green LED blink on communication), 2 mA @ 24 VDC (one communication every 5 seconds with red LED solid on), 4.5 mA @ 24 VDC (one communication every 5 seconds with amber LED solid on). CO sensing (using EC technology) for monitoring CO products from a smouldering fire, IR sensing for measuring ambient light levels and flame signatures, optical smoke detection and heat detection. multiple components of a fire: smoke, CO, light/flame, and heat. Process Monitors. The FST-951 intelligent addressable detector from Honeywell NOTIFIER features point ID capability that enables each detector address to be set with rotary address switches to provide exact detector locations. Your personal data will be used to support your experience throughout this website, to manage access to your account, and for other purposes described in our privacy policy. The FCO-851(A) Advanced Multi-Criteria Fire/CO Detector is a plug-in, addressable device that provides both fire and carbon monoxide (CO) detection. RYBB Fire Alarm has installed and is currently servicing a long list of residential and commercial locations in Miami, providing video surveillance, intrusion detection, and fire detection systems. NEMA 1. The FSP-951 photoelectric detectors unique optical sensing chamber is engineered to sense smoke produced by a wide range of combustion sources. Optional relay, isolator and sounder bases. The lithium-ion batteries in the umbrellas solar panels can overheat, posing fire and burn hazards. UL/ULC Listing. India FM, and CSFM Approved. The chairs can tip over or collapse when a consumer is seated in the chair, posing a fall hazard. Detector sensitivity and accuracy: Its very difficult to scientifically test how well a smoke/CO detector does its primary job without actually burning your house down. Will you be buying a large quantity of items? Note that we had lackluster results with several of these hooksand even if you do connect the alarm to your smart home hub, the ultimate usefulness of this connection can be limited. Remote testing capability. NOTIFIER by Honeywell i3 Series Photoelectric and Thermal Smoke Detector. a Temp 4 pattern for CO alarm indication. The link you selected is for a destination outside of the Federal Government. It is a normally-open device designed especially for fire detection and alarm systems. For CO, the detectors electrochemical sensing cell creates a separate signal for life safety CO combustibles with Hazardous Area, Explosion Proof, UL, Atex and CSA certifications. The beam operates primarily on the principle of light obscuration using infrared. That said, when paired with a smart thermostat, some smart smoke alarms can trigger the thermostat to shut down your HVAC system, so that smoke isnt pulled into your ventilation system and circulated all around your home. [. Notifier 30-3013 Explosion-Proof Smoke Detector for smoldering and rapidly growing fires. series bases recognize the System Sensor synchronization protocol, for use as a component of the general evacuation signal along with other System Sensor horns, horn strobes, and chimes when connected to a power supply or Fire Alarm Control Panel Calibration Gases. Thats a potential life saver all by itself. U.S. Consumer Product Safety Commission Spain UL listed. It is a normally-open device designed especially for fire detection and alarm systems. colorless, odorless and deadly gas that is virtually impossible to International Sites unit (smoke, CO, light/flame, and heat) to sense multiple components of a fire. Fixed gas leak detectors. Christopher Null is a veteran technology and business journalist. provides both fire and carbon monoxide (CO) detection. B2B Checkout Options: Designated Carrier and Tax-Exempt purchase Payment Options: Credit Card, Credit Card Over the Phone, PAYPAL, Wire Transfer and Check, Notifier System Sensor Mechanical Heat Detector, Notifier FST-951 Series Intelligent Addressable Thermal (Heat) Detector with FlashScan and CLIP protocol systems. Start your Search with category name, product name, part number, etc. NOTIFIER by Honeywell FPTI-951 Multi-Criteria Photo/Thermal/Infrared Detector with FlashScan and CLIP protocol systems. Denmark Dual LEDs for 360 visibility. combustibles with Hazardous Area, Explosion Proof, UL, Atex and CSA certifications. Wide angle and dual color LED indicator. Tyco Simplex 4098-9401 Electronic Heat Detector for Two-Wire Direct Connect with fixed temperature operation. rybbfirealarm.com@gmail.com Toll-Free Consumer Hotline | Time: 8 a.m. - 5.30. p.m. This can be a big benefit if you have a very large home and fear you might not hear an alarm going off elsewhere in the house. The 302-EPM-194 Thermotech rate-anticipation heat detector from Honeywell NOTIFIER operates within a controlled range of two to three degrees of their set points, regardless of the speed or rate of temperature rise. This doesn't affect our editorial independence. Together, we can find the right fire safety solution for your building empowering you to quickly respond to potential fires and evacuate people immediately. UL and FM approved. fco notifier addressable applications where moderate to heavy nuisance conditions exist that The FST-951H intelligent addressable detector from Honeywell NOTIFIER features point ID capability that enables each detector address to be set with rotary address switches to provide exact detector locations. This intelligent, addressable detector includes point ID capability that enables each detector address to be set with rotary address switches to provide exact detector locations.

Sitemap 9