Fully automatic, and industry best performance and efficiency. Once youre logged in to your account, create locations by touching the + from the Locations screen. Batteries contain acid, and caution must be taken when handling. 2. The DC controller is equipped with a charger for maintaining the battery in a ready state and recharging the battery after use when AC power is restored. Max 80-amp., Maintenance-Free Battery Instructions The Basement Watchdog Maintenance-Free Battery is compatible with most Basement Watchdog systems including the Basement, NEXSENS UW6-BB X2 Battery Backup Whats Included Battery enclosure mounting hardware (2) Mounting braces (2) 5/16-18, BATTERY BACKUP POWER BBP-AR-33-EBP Battery Cabinet Cabinet Overlook Dimension (D x W x H): 780 mm x 250. Service if required. 2.4 Ghz network is required. Zoeller uses a normally open operational float switch, and a normally closed high water float switch. It is the responsibility of the installing party to ensure that the float switch will not hang up on the pump apparatus or pit peculiarities and is secured so the pump will turn on and off. It is recommended that the pit be 18" (45.7 cm) in diameter or larger to. All electrical and safety codes must be followed including the National. If this. If they are not, call a qualified, licensed electrician. The LEDs will display information about the controller. Batteries with top terminals are recommended for ease of installation. After 1 second splash activation prevention delay, the DC backup pump will run, and the alarm will sound after 1 more second. There are two buttons on the front of the controller. Other visual information such as input status and battery level are available through the web and app interfaces.There are 2 ways to connect the Aquanot Fit to the Z Control cloud. Wet cell batteries contain acid, and proper precaution must be taken when handling. (b) The battery light will be yellow when charging. It is the responsibility of the installing party, to ensure that the float switch will not hang up on the pump apparatus. A completely drained battery may require up to 24 hours for full recharge. Know what your WiFi network is named (i.e. Connect the DC pumps plug into the controller terminal. You now should go back to the Z Control app to find your new device set up in the location you previously selected. These limits are designed, to provide reasonable protection against harmful interference in a residential, installation. Like most internet connected devices, the Fits WiFi connectivity should be used behind a secure firewall. Diverting water stream against wall of basin usually corrects an air lock problem. The Fits alert history on the Z Control Cloud will also be updated with the firmware update information, and notification to email accounts will occur. Some of these by-products can produce a rotten egg odor. Its possible that the Fit could perform an update immediately if one is available at the Z Control Cloud. DO NOT USE AN EXTENSION CORD. Alarm sounds during battery recharge cycle. Water powered emergency backup (a) Battery is low or pump may have blockage in screen, impeller, or piping system. It will look like ZCTL_Fit_xxxx where xxxx is the first 4 digits of your Fits Device ID. For best cooling, install wall mount configuration. Disconnecting the high water float will cause the pump to run. By connecting the Fit to the Z Control Cloud using the built-in WiFi, the user can set up free alert messages via email, text, and mobile app push notifications. WEP and Open networks are not compatible with the Fit. Create a free account at zcontrolcloud.com. size 27 deep-cycle battery, 175 minute reserve capacity, or larger, Do not let corrosion build up on the battery terminals, To check specific gravity, follow the instructions on a hydrometer (wet cell batteries only). If the LED is blinking and not in AP mode, press the Z Control button for 12 seconds and let go. You can always change a device to a different location in your account. Standing near the Fit, use your phone, tablet, or computer to look for the Fits SSID in your WiFi settings (see Figure B). Verify your WiFi network is connected to the internet and that it is broadcasting a visible, secure, 2.4Ghz network. The primary pump may come on, lower the water level in the sump back to its normal operating level, and shut off. This feature enables the sump pump alarm to provide instant alerts to homeowners whenever a flooding emergency occurs. (f) Float switch was not on for more than 1 second. Download the Z Control Mobile App! Open the Fit and explore current status, configuration settings, and commands available, such as Pump Test, Buzzer Test, Silence, etc. After up to 1 minute, the Fit will restart and return to normal operation. The Aquanot Fit Controller is designed for use with Z Control. Run water into the sump until the DC backup pump is activated by the operational float switch. (g) Make sure discharge piping is not blocked. Replace if necessary. sump pump system (25 pages), 12 volt dc battery backup pump (12 pages), Preassembled sump pump system with battery backup 12 v dc battery backup system with 115 v ac powered sump pump model m53 or m98 (25 pages), Multi-stage turbine effluent pumps (8 pages), Sewage/effluent/sump/dewatering (6 pages), Battery backup pedestal sump pump (8 pages), Manual will be automatically added to "My Manuals", Water Pump Zoeller AQUANOT SPIN 508 Installation Instructions Manual, Water Pump Zoeller Aquanot 508 Installation Instructions Manual, Water Pump Zoeller 503 Installation Manuals, Water Pump Zoeller AQUANOT 508 Fit Installation Instructions Manual, Water Pump Zoeller AquaNot 508 Fit Installation Instructions Manual, Water Pump Zoeller ProPak 508/53 Installation Instructions Manual, Water Pump Zoeller 5030 Series Owner's Manual, Water Pump Zoeller AquaNot 507 Key Installation Instructions Manual, Water Pump Zoeller 5054 Installation Instructions Manual, Water Pump Zoeller 53 Series Installation Instructions Manual, Water Pump Zoeller 55/59 Series Installation Instructions Manual, Water Pump Zoeller 55 Series Installation Instructions Manual. The Fit controller powers up expecting both switches to be connected. Carefully read the literature provided to familiarize yourself with specific details regarding installation and use. If this occurs, simply plug in both switches and then reset the alarms by holding the Silence button for 3 seconds. It is recommended that the pit be 18 (45.7 cm) in diameter or larger to accommodate both a primary and a DC backup pump. Connect to a separate electrical circuit from the primary pump. - Consult the dealer or an experienced radio / TV technician for help. Make sure the 115 V electrical supply circuit is equipped with fuses or, DC emergency pumps are designed for handling clear water. FITTINGS: An integrated DC pump discharge check valve, additional AC pump thread-in check valve, tee, and adapter are included. MAIL TO: P.O. Reconnect and refer to Installation Instructions. Do not use in septic tanks to pump effluent or in sewage pits to pump sewage. This DC battery backup system with built-in Wi-Fi provides free connectivity to theZ Control Cloud. Instructions for connecting directly are provided below under Use Your Mobile Device Or Computer To Connect Directly To The Fit Controller. The self-testing technology ensures the pump is ready to perform and contributes to its long-term reliability. Are you a contractor looking for a reliable pumping solution for residential applications? (a) To silence alarm if alarm will not reset, unplug the charger from 115 V wall outlet, then disconnect the black lead from charger on negative (-) battery post. Check the controller. The alarm can be silenced by pressing the Silence button. Install the Fit Controller (see Figure 3) by using the anchors provided. The installation kit includes the parts needed to install as in Figure 1. The above list also helps to troubleshoot connectivity issues. A check valve is incorporated in the discharge of the backup pump. AGM batteries also recommended. To use multiple batteries, order extra battery case with hookup wire (P/N 10-5184). Home > Backup Pump Systems > Aquanot Fit 508, PROFESSIONAL Series, self-testing, 12-volt DC battery backup system with built-in WiFi for Z Control connectivity. This revolutionary Aquanot sump pump offers the following: PUMP:Designed and tested for reliability, the Aquanot 508 DC sump pump works alongside submersible or pedestal pumps to provide up to 6 hours of continuous high-performance pumping when the primary pump power is interrupted or more capacity is needed. in septic tanks to pump effluent or in sewage pits to pump sewage. Check out theZoeller YouTube Channelfor Webinars, Tips, Trainings, and Product Videos! If the operational float is down, and the DC pump is underwater, the pump will run until the float lowers and the pump is no longer pumping water, or the run timer expires. The installation of DC automatic backup pumps requires the use of a variable, level float switch for operation. Enter the passphrase for the network you chose in the field indicated. The power supply for your DC control system. its SSID) and its password. The controller will recognize the difference between a pump that is pumping air vs. a pump that is pumping water. (c) Under certain conditions the pump may continue to run on a low battery without sufficient power to remove water. (b) If immediate usage is required, remove and replace dead battery with a fully recharged battery. Sk3182 Aquanot Spin 508 Installed System, Technical Data, Aquanot Spin 508 FM3165: 60 Hz, Installation Instructions, Aquanot 508 Spin FM3166: 60 Hz, Sales Slick, Monitor Products With Z Control, Aquanot Maintenance Free Batteries FM3303. Pump runs but moves very little or no water. Check out theZoeller YouTube Channelfor Webinars, Tips, Trainings, and Product Videos! This equipment generates, uses and can radiate radio frequency, energy and if not installed and used in accordance with the instructions, may, cause harmful interference to radio communications. If so, 2 things will happen: On the setup screen (see Figure C), press the WiFi Scan button, scroll down to see the list of WiFi signals found, and choose the WiFi network you want the Fit to use for internet connectivity. Risk of electric shock. The 508 is made by Zoeller in Indiana. The second method is to use your mobile device or computer to connect to the Fit directly. Primary sump pump included with ProPak model: 508-0006 with model 53, 508-0007 with model 98. Stop by thedistributor in your areafor a closer look, or contact them for additional product and pricing information today. It is the owners responsibility to check the battery and battery connection at least once a month. These instructions are below under Use the Mobile App. Also consider the Aquanot Fit 508 Systems, which can add remote access and mobile notifications through the Z Control Cloud platform. When ready to add a device, choose the desired location name and then touch the + to start adding a device. Disconnect the primary pump from its power source before touching any component in the sump pit. Press the slotted end of the discharge tee onto the check valve and secure with a hose clamp. Soapy water is recommended as a lubricant. (a) The primary pump will come on, lower the water to the normal operating level and shut off. (-) lead to negative battery terminal. The controller also has smart float logic that is designed to prevent a continuous running pump (or run dry pump condition). Testing for ground. Positive (+) lead to positive terminal and black neg. Install float switches as seen in Figure 1. This could take up to a minute or so. Soapy water is recommended as a lubricant. The top rubber stop is not needed unless the on level needs to be lowered. (e) Remove pump. connected to your outlet. CONTROLLER:The Fit controller is an automatic charging and protection system, including a low battery indicator and alarm, redundant high water switch, self-testing technology, and built-in Wi-Fi. ), or other abrasive or corrosive substances, wash towels or feminine sanitary products, etc. The warranty set out in the paragraph above is in lieu of all other warranties expressed or implied; and we do not authorize any representative or other person to assume for us any other liability in connection with our products.Contact Manufacturer at, 3649 Cane Run Road, Louisville, Kentucky 40211, Attention: Customer Support Department to obtain any needed repair or replacement of part(s) or additional information pertaining to our warranty.MANUFACTURER EXPRESSLY DISCLAIMS LIABILITY FOR SPECIAL, CONSEQUENTIAL OR INCIDENTAL DAMAGES OR BREACH OF EXPRESSED OR IMPLIED WARRANTY; AND ANY IMPLIED WARRANTY OF FITNESS FOR A PARTICULAR PURPOSE AND OF MERCHANTABILITY SHALL BE LIMITED TO THE DURATION OF THE EXPRESSED WARRANTY.Some states do not allow limitations on the duration of an implied warranty, so the above limitation may not apply to you. If either float switch is missing/unplugged, it will create an immediate alarm condition. Prop 65 Warning for California residents: Cancer and Reproductive Harm-. Solvent weld the discharge reducer fitting to the discharge tee as shown in Figure 4. These pumps have not been investigated for use in swimming pools and marine areas. This will prevent the most common troubleshooting issues. Flashing LEDs for conditions such as bad/disconnected battery or power outage, for example, cant be cleared by Silence/Reset. The preferred method of installation for backup pumps is shown in Figure 1. Note that the charger may not begin charging for several minutes. For your protection, always disconnect the power supply from its power, source before handling the components of your DC backup pump or the, Installation and servicing of electrical circuits and hardware should be. The LEDs have specific patterns and behaviors that differ from other products on the market. (b) Baffle the incoming stream of water to reduce turbulence. To use multiple batteries, order extra battery case with hook-up wire (10-5184). - Increase the separation between the equipment and module / product. If this condition exists, the incoming water. Contact the manufacturer and ask for recommendations to prevent the alarm activation. If the operational float is up during high water, unit will alarm and high water float light will illuminate. Get a reliable emergency backup battery pump system that fills the void when the primary pump underperforms or is unavailable due to a power failure. (d) Check 30 amp fuse on controller (see fig. If an update is taking place, the Z Control LED will flicker for up to 1 minute while the update is downloaded. Consult a networking professional for specific questions about firewalls. Made from non-corrodible polyethylene. Service battery if required. Repair and service of your DC backup system should be performed by an authorized service station. Any over the air firmware updates that have been installed will be retained. Since the high water float does not have a sufficient pumping range, the controller will turn the pump off once 30 seconds have elapsed or the pump begins spinning in air. Remove all parts from the shipping carton, and make sure all parts are included. in all pumping applications. The power supply for your DC control system plugs directly into the 115 V outlet. Each pump is individually tested and achieves 35 GPM at 10 at 12.7 volts. Each pump is individually tested and achieves 35 GPM at 10 at 12.7 volts. The alarm will turn off. Install the operational float switch bracket above the on level of the primary pump using the clamp provided. Zoeller Pump Company has established an extensive network of Aquanot Fit 508 Battery Backup distributors to supply this superior product to contractors nationwide. The battery LED will be yellow during normal charging operation. The DC emergency pump system requires a good quality, 12 volt battery to obtain maximum pumping time during a power outage. (a) Check for low battery. (b) If power has been restored and water in sump remains high check primary pump. The battery will indicate its condition when the controller has DC power. Take care that the intake of the DC pump is set above the intake of the primary pump. Battery will recharge if green System Ready LED indicates power has been restored and the float switch is in the off position. on ZOELLER AquaNot 508 Fit 12V DC Battery Backup Pump Instruction Manual, ZOELLER AquaNot 508 Fit 12V DC Battery Backup Pump, ZOELLER FM2931 Apak Outdoor Alarm Instruction Manual, REDARC BCDC124D DC Battery Charger Instructions, THE BASEMENT WATCHDOG BW-27AGM Sump Pump Battery Instructions, NEXSENS UW6-BB X2 Battery Backup User Manual, BATTERY BACKUP POWER BBP-AR-33-EBP Battery Cabinet Installation Guide, AquaNot 508 Fit 12V DC Battery Backup Pump, OBSBOT 2469741 Smartphone Holder User Manual, TCL S334 HD LED Smart Android TV User Guide, Danby DDR050BCWDB-ME-6 Dehumidifier Owners Manual, 32LQ630B6LA 32-Inch LG Smart TV Owners Manual, LG 15Z95P Series 15Z95P-P.AAE8U1 15-Inch Ultra-Lightweight and Slim Laptop Owners Manual, AT&T DECT 6.0 Cordless Telephone Manual[DL72210, DL72310, DL72340, DL72350], TruMedic InstaShiatsu+ Foot Massager [IS-4000i] Instruction Manual, Glory Fit P32A Intelligent Smart Watch User Manual, 35 GPM at 10 (113 LPM at 3 m) at 12.7 volts, 8 (2.4 m) AC power cord, 6 (1.8 m) DC charging cable, connections for pump, operation switch, high water switch, Snap tight lid, keeps battery safe and clean. In addition, the user can verify the Fits readiness, remotely silence alarms and reset the unit, configure settings, and modify how notifications are sent. Some states do not allow the exclusion or limitation of incidental or consequential damages, so the above limitation or exclusion may not apply to you.This warranty gives you specific legal rights and you may also have other rights which vary from state to state. (g) Hold Silence/Reset button for 3 seconds to reset the controller and clear any alarms or indicators. We offer both a water/acid deep-cycle battery and a maintenance-free AGM battery which can run the pump continuously for over 5 hours. Lower the operational float switch after the alarm sounds. Also, some of these by-products can cause a CO detector to falsely activate. Allow access to the camera so you can scan the data matrix. Can be held for 3+ seconds to reset (or clear) alarms and LEDs. After up to 1 minute, the Fit will restart and return to normal operation. The pump is self-priming and specifically designed and manufactured by Zoeller as a purpose-built DC sump pump, rather than a repurposed bilge pump. TECHNOLOGY: This charger uses the latest switch mode technology available. If the passphrase is correct, the Fit will connect to the network and start sending status updates to zcontrolcloud.com. Now the app will provide several instruction screens about scanning the data matrix, joining the Fits network, and then LEAVING the app and how to come back. When the float is lowered, the pump will turn off, but the yellow DC Pump LED will not persist. When the captive screen opens (see Figure C in next section), use the Wifi Scan button to find the Wifi network you want the Fit to use, select it from the list provided at the bottom of the screen (you may need to scroll), and type the Passphrase in the field. Some battery types used in battery backup systems, regardless of brand or manufacturer, have the potential to give off gaseous by-products when charging. After 1-second splash activation prevention delay the pump will turn on, the alarm will sound, and the light will alert of high water. Check installation of the high water switch taking care that it is installed so that its on point is higher than the on point of the operational switch. Verify your WiFi router is connected to the internet and that it is broadcasting a visible, secure, 2.4Ghz network. Comment document.getElementById("comment").setAttribute("id","af99ef89565903687b7618e46368af53");document.getElementById("afe6277d1c").setAttribute("id","comment"); Save my name, email, and website in this browser for the next time I comment. If the operational float is held on while there is no water to pump, the controller will turn the pump on and off a few times before running the pump continuous. The LED will now be off, indicating the Fit is in AP Mode. (c) Check for low battery. If the primary pump is installed, disconnect power. (b) Check all wire terminal points. Do not operate in > 80 F environment. Do not use gel batteries or automotive batteries. Electrical Code and all applicable local codes. If the operational float was never installed, the alarm and red flashing Float Status LED will occur for 4 hours and then turn off. (d) The alarm will sound approximately 1 second after the pump starts to run. Apply AC Power to the Fit. This will instruct the controller to NOT alarm for the missing operational float and reset the unit. CONTROLLER: The Spin controller is an automatic charging and protection system, including a low battery indicator and alarm, self-testing technology, and an optional high water switch. DO NOT USE AN EXTENSION CORD. Home Zoeller ZOELLER AquaNot 508 Fit 12V DC Battery Backup Pump Instruction Manual. Plug the controller into the 115 V wall outlet. Select a location for the battery and the controller. As a safety measure each electrical outlet should be checked for ground using an Underwriters Laboratory listed circuit analyzer, which will indicate if the power, neutral and ground wires are correctly connected to your outlet. Occasionally, products are damaged during shipment. Installation and servicing of electrical circuits and hardware should be performed by a qualified, licensed electrician. Manufacturer warrants, to the purchaser and subsequent owner during the warranty period, every new product to be free from defects in material and workmanship under normal use and service, when properly used and maintained, for a period of 3 years from date of purchase by the end user. Zoeller Pump Company is a family-owned and -operated business thats been designing and manufacturing high-quality sump pumps and other products for more than 80 years. Move the switch up and down, ensuring free movement without interference from any obstructions inside the sump or lid. Actual times will vary depending on static head, volume of water entering the pit, and the condition of the battary. Use the below links from your mobile device. As one of the United States oldest independently owned pump manufacturers, the company brings an abundance of experience that benefits contractors and end users. As a safety measure each electrical outlet should be. Firmware Updates:The Fit is capable of OTA, or over the air firmware updates. Hold silence button for 3 seconds to reset the Fit controller. Do not use primary pump circuit. Use the Mobile App (iOS and Android) Before you begin: These basic instructions will not detail every step, but provide an overview of what the app will do. The location must be within 6' (1.8 m) of the, control box and battery. Diagnostic logic will recognize and prevent several common issues. For example, the controller is able to recognize potential air lock situations and remedy with an on/off/on/off/on routine proven to purge the problematic air from the pump. These times are based on continuous pumping at 8 (2.4 m) of static head. The yellow LED can be cleared by holding the Silence button for 3 seconds to reset. A 100+ amp hour battery will provide approximately 5.5 hours or more of continuous pumping time in a sump pump installation with 8 (2.4 m) of head pressure. The Fit offers true redundancy for pump operation that competitors products do not have.Before leaving the installation site, the installer must initiate a Reset by holding the Silence button for 3 seconds. Parts that fail within the warranty period, that inspections determine to be defective in material or workmanship, will be repaired, replaced or remanufactured at Manufacturers option, provided however, that by so doing we will not be obligated to replace an entire assembly, the entire mechanism or the complete unit. Turbulence caused by high-velocity incoming water can, cause sump pumps to airlock. If the Fit successfully connects to the cloud through the hotspot, then the conflict likely has something to do with the router settings. Self testing 12 Volt backup sump pump system. If the signal is questionable, your network may not be able to provide a stable connection for the Fit. Ensure the O-ring is properly located on the check valve. If you only see 5 Ghz networks, you may need to log into your dual band router to choose to broadcast the networks separately. The installation of DC automatic backup pumps requires the use of a variable level float switch for operation. Double check that you know the correct password and exactly how it is spelled, including capitalization. Double check you know the correct password and exactly how it is spelled, including capitalization. Know what your WiFi network is named (i.e. If water was pumped, the Yellow DC Pump LED and alarm will remain on, indicating that the pump ran and pumped water. Another unique feature of the Zoeller battery backup 508 is the ability of the system to recharge automatically. The Z Control LED will be solid and all other LEDs will turn off while the update is being installed. Check flow of water incoming to sump. Push the Silence button when the pump is running. If the signal is questionable, your network may not be able to provide a stable connection for the Fit. Verify that your mobile device has working WiFi and detects a strong signal from your WiFi network when when you are standing next to the Fit. Use of the included plastic battery box is recommended to keep the battery safe and clean. It is designed to protect against flooding during power outages or primary pump failure. No allowance will be made for shipping charges, damages, labor or other charges that may occur due to product failure, repair or replacement.This warranty does not apply to and there shall be no warranty for any material or product that has been disassembled without prior approval of Manufacturer, subjected to misuse, misapplication, neglect, alteration, accident or uncontrollable act of nature; that has not been installed, operated or maintained in accordance with Manufacturers installation instructions; that has been exposed to outside substances including but not limited to the following: sand, gravel, cement, mud, tar, hydrocarbons, hydrocarbon derivatives (oil, gasoline, solvents, etc. Technical data, Aquanot 508 Fit FM3124: 60 Hz, Installations Instructions, Aquanot 508 Fit_FM3120: 60 Hz, Aquanot Maintenance Free Batteries FM3303, Z Control Enabled notification and remote access, Z Control Cloud and App (see links below). This is to purge a suspected air lock. ocate the Fits Device ID and data matrix on the top sticker. Proof of purchase is required. Make certain the clamp is tight on the pipe to avoid slippage.

Sitemap 25